4430 IP Netflow settings

Currently, I am seeing my proc queue hit 100 for flow meter logging over a  24hr period of time. Is this service affecting for the overall routing of this device?

Queue                          Max Depth (%)

------------------------------ -------------

PC Config                                  2

PacketRouting                             62

FrontPanel                                 0

ICP Session                                0

RouteTableTick                             2

OSPF                                       0

IP Events                                  1

RSTP                                       0

RSTP                                       0

IKE                                        0

IPSecKeyGen                                0

Flow Meter Logging                       100

CFM Maint                                  0

BGP Thread                                 0

AUTOLINKQ                                  0

HttpClientQ                                0

RSTP                                       4

UDP In                                    17

Also, should eth0/2 be the source since it is the inside interface or should the source be the WAN interface that I have configured for netflow?

ip flow export destination xxx.xxx.xxx 2055 source gigabit-ethernet 0/2

ip flow cache timeout active 1

ip flow top-talkers

interface gigabit-eth 0/1

    speed 1000 nonegotiate

  ip address  xxx.xxx.xxx.xxx

  ip ffe

  ip mtu 1500

  ip flow ingress

  ip flow egress

  no rtp quality-monitoring

  bandwidth 300000

  qos-policy out sonet

  no awcp

  no shutdown

!

!

interface gigabit-eth 0/2

  description Fast Ethernet

  ip address  xxx.xxx.xxx.xxx

  ip ffe

  no shutdown

0 Kudos
2 Replies
Anonymous
Not applicable

Re: 4430 IP Netflow settings

:

Thank you for asking this question in the support community.  Yes, with this minimal snapshot, the processor appears to be taxed due to the load of routing, combined with the flow meter (traffic monitoring feature).  Here is the Configuring Integrated Traffic Monitoring in AOS guide for reference.  ITM recommendations and limitations start on page 8:

Using ITM does slightly affect memory and CPU usage on your AOS product. Depending on the amount of available memory, capturing large amounts of traffic flow data may fill up the flow cache. An increase in memory or a reduction in data capture (by using sampling, for example) can alleviate this problem. To keep ITM memory and CPU usage to a minimum, RapidRoute must be enabled on each interface to be monitored using the ip ffe command from the interface configuration mode.

Please, let me know what additional questions or information you have.  I will be happy to help in any way I can.

Levi

Anonymous
Not applicable

Re: 4430 IP Netflow settings

:

I went ahead and flagged this post as "Assumed Answered." If any of the responses on this thread assisted you, please mark them as Correct or Helpful as the case may be with the applicable buttons. This will make them visible and help other members of the community find solutions more easily. If you still need assistance, we would be more than happy to continue working with you on this - just let us know in a reply.

Thanks,

Levi