Need to know the correct interface config settings to make two TA850's work back-to-back (FXS to FXO) over a T1 Crossover.

Labels (2)
Tags (5)
0 Kudos
1 Solution

Accepted Solutions
Anonymous
Not applicable

Re: Configuring two TA850's to work back-to-back (FXS to FXO) over T1 crossover

Jump to solution

The T1s just need to match settings on each side.  Same coding and framing.  The same DS0s assigned to the FXS and FXO.  One side will need to be set to provide timing and the other side to receive it.  At that point as long as dial tone and talk battery is coming in on the FXO side the connection should be fine.

View solution in original post

0 Kudos
2 Replies

Re: Configuring two TA850's to work back-to-back (FXS to FXO) over T1 crossover

Jump to solution

These have the RCU modules

Anonymous
Not applicable

Re: Configuring two TA850's to work back-to-back (FXS to FXO) over T1 crossover

Jump to solution

The T1s just need to match settings on each side.  Same coding and framing.  The same DS0s assigned to the FXS and FXO.  One side will need to be set to provide timing and the other side to receive it.  At that point as long as dial tone and talk battery is coming in on the FXO side the connection should be fine.

0 Kudos