Anonymous
Not applicable

502 error

Jump to solution

I am getting a error, after I program my 908e. The error is "502 bad gateway" Where would I start looking.

Labels (1)
0 Kudos
1 Solution

Accepted Solutions
Anonymous
Not applicable

Re: 502 error

Jump to solution

tazz29063,

Thanks for posting.  First, verify with a 'ping' that we can reach the SIP server.  Correct any IP address and/or route issue if this fails.  Then, I agree that we need to check your voice trunks, trunk groups, and any PRI interfaces.  Verify that your voice trunks are connected to the trunk groups as shown in the example for a SIP trunk below.

voice trunk T01 type sip

  sip-server primary 1.1.1.1

!

voice grouped-trunk SIP

   trunk T01

  accept $ cost 0

If you have a PRI trunk, it should have a corresponding "connected" grouped-trunk as well.  Next, I would check all your interfaces with "show interfaces" to verify that your interfaces are up.  In particular, your PRI interface should show an active D channel under "Channel Status".  If you do not see any issue in any of these places, we will likely need to see your configuration and possibly a debug output of a test call.

We would be glad to review your configuration as a first step, but be sure to remove any passwords, IP addresses, phone numbers, etc. that you do not want public.

Thanks!

David

View solution in original post

0 Kudos
3 Replies
Anonymous
Not applicable

Re: 502 error

Jump to solution

I believe that this usually means there is no route (either configuration error or the T1/ PRI is down)

Anonymous
Not applicable

Re: 502 error

Jump to solution

tazz29063,

Thanks for posting.  First, verify with a 'ping' that we can reach the SIP server.  Correct any IP address and/or route issue if this fails.  Then, I agree that we need to check your voice trunks, trunk groups, and any PRI interfaces.  Verify that your voice trunks are connected to the trunk groups as shown in the example for a SIP trunk below.

voice trunk T01 type sip

  sip-server primary 1.1.1.1

!

voice grouped-trunk SIP

   trunk T01

  accept $ cost 0

If you have a PRI trunk, it should have a corresponding "connected" grouped-trunk as well.  Next, I would check all your interfaces with "show interfaces" to verify that your interfaces are up.  In particular, your PRI interface should show an active D channel under "Channel Status".  If you do not see any issue in any of these places, we will likely need to see your configuration and possibly a debug output of a test call.

We would be glad to review your configuration as a first step, but be sure to remove any passwords, IP addresses, phone numbers, etc. that you do not want public.

Thanks!

David

0 Kudos
Anonymous
Not applicable

Re: 502 error

Jump to solution

tazz29063,

I went ahead and flagged this post as "Assumed Answered".  If any of the responses on this thread assisted you, please mark them as Correct or Helpful as the case may be with the applicable buttons.  This will make them visible and help other members of the community find solutions more easily.  If you still need assistance, I would be more than happy to continue working with you on this - just let me know in a reply.