vonluck
New Contributor

Config for HST-3000 testing

I have been trying to dry run some of my test equipment on an Adtran 908e at my desk.  The problem I’m running into is that my HST-3000 can’t pull information from the D-channel on the 908e.  I was wondering if there was an easy config change that would allow my tester access to the information it needs on the Adtran?

Thanks,

von Luck

0 Kudos
7 Replies
Anonymous
Not applicable

Re: Config for HST-3000 testing

It should work just fine.

Are you sure the D-Channel is up?

Make sure the wiring is correct.

The 900e series is wired differently than the 900.

vonluck
New Contributor

Re: Config for HST-3000 testing

My 908e and HST-3000 have power, I have plugged a cat 5 into the net 4 port on the Adtrans which is no shut on the interface:


interface t1 0/4


  tdm-group 1 timeslots 1-24 speed 64


  no shutdown


!


!


interface pri 1


  connect t1 0/4 tdm-group 1


  role network b-channel-restarts disable


  no shutdown


I dont get link lights on my HST-3000 and the 908e displays a solid red light accross all of its net indicators.

Thanks for the fast reply

Anonymous
Not applicable

Re: Config for HST-3000 testing

Try using a T1 cross over cable.

vonluck
New Contributor

Re: Config for HST-3000 testing

Power cycled both devices and plugged in a T1 crossover and I'm still having the exact same issues.

von Luck

Anonymous
Not applicable

Re: Config for HST-3000 testing

If everything is red then the T1 is not up.

vonluck
New Contributor

Re: Config for HST-3000 testing

Sorry, I should have been more specific in my initial post.  The 908e is not connected to anything other than my computer and my HST-3000.  My intent is to navigate through test windows on my HST while the 908e is disconnected from the outside line.  I gather for this to occur the HST needs access to the D-channel to spoof the meter into thinking the PRI is up.  By doing this it unlocks the additional menus I want to navigate through.  Sorry for any confusion.

Thanks,

von Luck

vonluck
New Contributor

Re: Config for HST-3000 testing

I have worked through the connection issues with the HST and the device and currently I am at the initial problem.  The HST is not detecting a D-channel which prevents me from navigating through some of my menues.  Is there a way to spoof my device with a config change on the 908e?

Thanks,

von Luck