The version that I am seeing the subject scenario is OS version R10.9.4.E.
2015.09.15 12:41:58 PPP.NEGOTIATION LCP up
2015.09.15 12:41:58 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:41:58 PPP.NEGOTIATION LCP down
2015.09.15 12:42:08 PPP.NEGOTIATION LCP up
2015.09.15 12:42:08 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:08 PPP.NEGOTIATION LCP down
2015.09.15 12:42:18 PPP.NEGOTIATION LCP up
2015.09.15 12:42:18 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:18 PPP.NEGOTIATION LCP down
2015.09.15 12:42:24 T1.t1 0/3 CSS 24 hr threshold exceeded
2015.09.15 12:42:28 PPP.NEGOTIATION LCP up
2015.09.15 12:42:28 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:28 PPP.NEGOTIATION LCP down
2015.09.15 12:42:38 PPP.NEGOTIATION LCP up
2015.09.15 12:42:38 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:38 PPP.NEGOTIATION LCP down
2015.09.15 12:42:48 PPP.NEGOTIATION LCP up
2015.09.15 12:42:48 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:48 PPP.NEGOTIATION LCP down
2015.09.15 12:42:58 PPP.NEGOTIATION LCP up
2015.09.15 12:42:58 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:42:58 PPP.NEGOTIATION LCP down
2015.09.15 12:43:07 PPP.NEGOTIATION LCP up
2015.09.15 12:43:07 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:43:07 PPP.NEGOTIATION LCP down
2015.09.15 12:43:17 PPP.NEGOTIATION LCP up
2015.09.15 12:43:17 PPP.ERRORS Multilink is not enabled at the ppp destination
2015.09.15 12:43:17 PPP.NEGOTIATION LCP down
Current Performance Statistics:
60 Errored Seconds, 0 Bursty Errored Seconds
0 Severely Errored Seconds, 0 Severely Errored Frame Seconds
0 Unavailable Seconds, 0 Path Code Violations
0 Line Code Violations, 60 Controlled Slip Seconds
0 Line Errored Seconds, 0 Degraded Minutes
Ultimately this is preventing the TA-908 from syncing up with my Cisco7613. I have tried almost every response from the community boards and none of them have worked so far. I do not have a PBX with the router, and timing sources were both implemented within the router. The web GUI was disabled before the router was shipped out to the customer. Please advise your best advice.
Thanks,
Robert Nooks
Data Implementation
614-973-6383
I don't think the TA series supports independent clock sources on the T1's so they all need the same reference. I assume you want to get clock from the Cisco?
!
interface ppp 1
ip address 1.1.1.1 255.255.255.252
ppp multilink
no shutdown
cross-connect 1 t1 0/1 1 ppp 1
cross-connect 2 t1 0/2 1 ppp 1
cross-connect 3 t1 0/3 1 ppp 1
cross-connect 4 t1 0/4 1 ppp 1
!
!
!
!
timing-source t1 0/1
timing-source t1 0/3 secondary
timing-source t1 0/4 secondary
timing-source t1 0/2 secondary
!
I have tried that as well. All of the clock sources are matching up. Still receiving the same error as before.
Robert Nooks
Provisioning Technician
National Service Delivery Implementations Team
robert.nooks@centurylink.com
(614) 973-6383 (IP phone)
Office Hours: Mo - Fr 0600 - 1600 Eastern