e0051723
New Contributor
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Report Inappropriate Content
06-09-2020
10:17 AM
OPTI-3 error message
receiving a "Manual Abnormal (MAN) condition" alarm on the CPE end of a ptp DS3... searched most of the online documentation and can't seem to find an actual description of what this means.... anyone know?
1 Reply
tmccarley
Adtran Team
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Accept as Solution
- Report Inappropriate Content
01-05-2021
01:32 PM
Re: OPTI-3 error message
MAN alarm is an Alert that the Working OC3 and/or Protect OC3 is in an Out of Service, Maintenance State, to clear that alarm you would just put the OC3 In Service.
Out Of Service, Maintenance is a Service state used to allow Loopbacks, and inhibit Critical or Major Alarms. Payload Data will still pass when in that state.