BIG NEWS! The Adtran Support Community is moving! In the next few weeks it will be housed in a new location. Be sure to visit our NEW Adtran Community before the end of July to check it out and verify that you can access all the resources and features that you need. If you discover any issues with your account or access, or just want to let us know about your experience, be sure to use our Feedback Form to let us know!
cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
Anonymous
Not applicable

Monitoring the signal from the CPE using the monitor jacks on an HxTU-R

Question:

What is the direction of the signal from the CPE when using the monitor jacks on HxDSL HTUR?

Response:

Applies to HxTUR:

1223424     T200 H4TU-R

1223426     T200 H4TU-R

1223024     T200 H2TU-R

1223026     T200 H2TU-R

1246026     T200 HTU-R

Using a test set with 2 receivers.

  • The TX or T/R is a monitor from the CPE/DCP toward the Network or HxTUC.
  • The RX or T1/R1 is from the local loop or HxTUC/Network.  Local Loop is the copper from the HxTUC to the HxTUR.

The signal is MON Non-Intrusive, do not use a Terminated reading.  The test set can only monitor a REC. signal.