Greetings,
I know it is possible to use this device as a gateway from SIP to PRI, but what about the reverse? We have legacy PRI's in the building and our new phone switch can only take SIP trunks (asterisk bases). I saw a post about a sample configuration for this but was unsure if this would work with this model 924e.
Is there a configuration that could work with this? Our phone carrier is actually using 2 PRI's, so the config would need to reflect that. I am having high hopes that this is possible.
Thank you,
Edward
Hello,
Yes this is possible.
I threw this together hopefully I didnt typo or miss anything:
interface t1 0/3
tdm-group 1 timeslots 1-24 speed 64
no shutdown
interface t1 0/4
tdm-group 1 timeslots 1-24 speed 64
no shutdown
interface pri 1
description pri 1
role user
connect t1 0/3 tdm-group 1
no shutdown
interface pri 2
description pri 2
role user
connect t1 0/4 tdm-group 1
no shutdown
isdn-group 1
connect pri 1
isdn-group 2
connect pri 2
voice trunk T01 type isdn
description "PRI1"
connect isdn-group 1
voice trunk T02 type isdn
description "PRI2"
connect isdn-group 2
voice trunk T03 type sip
description "PBX"
sip-server primary [IP of PBX]
voice grouped-trunk PRITRUNK
trunk T01
trunk T02
accept $ cost 0
voice grouped-trunk PBXTRUNK
trunk T03
accept $ cost 0
Your config looks great! I'm trying to figure out a way to test it out as a proof of concept now that it's up. Thank you for the help.
Hello,
Yes this is possible.
I threw this together hopefully I didnt typo or miss anything:
interface t1 0/3
tdm-group 1 timeslots 1-24 speed 64
no shutdown
interface t1 0/4
tdm-group 1 timeslots 1-24 speed 64
no shutdown
interface pri 1
description pri 1
role user
connect t1 0/3 tdm-group 1
no shutdown
interface pri 2
description pri 2
role user
connect t1 0/4 tdm-group 1
no shutdown
isdn-group 1
connect pri 1
isdn-group 2
connect pri 2
voice trunk T01 type isdn
description "PRI1"
connect isdn-group 1
voice trunk T02 type isdn
description "PRI2"
connect isdn-group 2
voice trunk T03 type sip
description "PBX"
sip-server primary [IP of PBX]
voice grouped-trunk PRITRUNK
trunk T01
trunk T02
accept $ cost 0
voice grouped-trunk PBXTRUNK
trunk T03
accept $ cost 0
Your config looks great! I'm trying to figure out a way to test it out as a proof of concept now that it's up. Thank you for the help.
Add to Unified's configuration to prevent random ticking sounds and slanted faxes:
timing-source t1 0/3
timing-source t1 0/4 secondary