With the TA908e (L5 version) with one DSP, how many PRI calls can be made simultaneously?
1 Solution
Accepted Solutions

Anonymous
Not applicable
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Not the Solution
- Report Inappropriate Content
05-31-2013
11:28 AM
mrmac:
You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.
Regards,
Ronnie Colvin
Adtran Applications Engineering
--------------------------------
2 Replies

mrmac
New Contributor
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Accept as Solution
- Report Inappropriate Content
05-23-2013
10:55 AM
Re: DSPs
Is it 30 per DSP?

Anonymous
Not applicable
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Not the Solution
- Report Inappropriate Content
05-31-2013
11:28 AM
mrmac:
You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.
Regards,
Ronnie Colvin
Adtran Applications Engineering
--------------------------------