BIG NEWS! The Adtran Support Community is moving! In the next few weeks it will be housed in a new location. Be sure to visit our NEW Adtran Community before the end of July to check it out and verify that you can access all the resources and features that you need. If you discover any issues with your account or access, or just want to let us know about your experience, be sure to use our Feedback Form to let us know!
cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
mrmac
New Contributor

With the TA908e (L5 version) with one DSP, how many PRI calls can be made simultaneously? 

Labels (1)
0 Kudos
1 Solution

Accepted Solutions
Anonymous
Not applicable

Re: DSPs

Jump to solution

mrmac:

You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.

Regards,

Ronnie Colvin

Adtran Applications Engineering

--------------------------------

View solution in original post

0 Kudos
2 Replies
mrmac
New Contributor

Re: DSPs

Jump to solution

Is it 30 per DSP?

Anonymous
Not applicable

Re: DSPs

Jump to solution

mrmac:

You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.

Regards,

Ronnie Colvin

Adtran Applications Engineering

--------------------------------

0 Kudos