Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit
2 Replies

Anonymous
Not applicable
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Accept as Solution
- Report Inappropriate Content
09-28-2016
02:29 PM
Re: Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit
Based on the 900_900e comparision chart, the 4243908F2 can support 4 WAN T1 circuits or 4 TDM voice circuits for terminating T1/PRI to a PBX.
The maximum number of calls would be limited to 60 TDM to IP conversions on the model you are using. I have attached the sheet for reference.


Honored Contributor
- Mark as New
- Bookmark
- Subscribe
- Mute
- Subscribe to RSS Feed
- Permalink
- Accept as Solution
- Report Inappropriate Content
10-06-2016
12:19 AM
Re: Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit
4 PRIs yes. 92 concurrent calls, no. There are 60 DSP resources in hardware, each of which can handle one RTP-TDM call. We've never pushed 60 but I seem to recall a couple of DSPs reserved for internal use. T.38 fax is limited to 30 concurrent. It'll do two PRIs plus a handful of FXS ports at the same time just fine.
Also no NFAS. Each physical PRI needs a D-channel.