The Adtran community holiday season is starting next week! The holiday period will span from December 21, 2024 to January 6, 2025. During this time, responses to feedback form submissions may be delayed. If you are encountering product issues, you can reach out to Adtran support at any time.
cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
cfrass66
New Contributor

Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit

I was able to configure 4 pri's off this unit and they are all up. Just want to make sure this is approved and can the unit support 92 concurrent calls.

Labels (2)
0 Kudos
2 Replies
Anonymous
Not applicable

Re: Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit

Based on the 900_900e comparision chart, the 4243908F2 can support 4 WAN T1 circuits or 4 TDM voice circuits for terminating T1/PRI to a PBX.

The maximum number of calls would be limited to 60 TDM to IP conversions on the model you are using. I have attached the sheet for reference.

jayh
Honored Contributor
Honored Contributor

Re: Platform: Total Access 908e (3rd Gen), part number 4243908F2SBC : How many PRI's can be supported off this unit

4 PRIs yes. 92 concurrent calls, no. There are 60 DSP resources in hardware, each of which can handle one RTP-TDM call. We've never pushed 60 but I seem to recall a couple of DSPs reserved for internal use. T.38 fax is limited to 30 concurrent. It'll do two PRIs plus a handful of FXS ports at the same time just fine.

Also no NFAS. Each physical PRI needs a D-channel.